<?xml version="1.0" encoding="UTF-8"?>
<xml><records><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">A. Augustyn</style></author><author><style face="normal" font="default" size="100%">Przemysław Kowalski</style></author><author><style face="normal" font="default" size="100%">Leszek Luchowski</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Krzysztof Skabek</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">System for toolmark analysis in forensic laboratory</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2002</style></year></dates><secondary-title><style face="normal" font="default" size="100%">Archiwum Informatyki Teoretycznej i Stosowanej</style></secondary-title><pages><style face="normal" font="default" size="100%">3–16</style></pages><volume><style face="normal" font="default" size="100%">14</style></volume><number><style face="normal" font="default" size="100%">1</style></number><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>47</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">A. Augustyn</style></author><author><style face="normal" font="default" size="100%">Przemysław Kowalski</style></author><author><style face="normal" font="default" size="100%">Leszek Luchowski</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Krzysztof Skabek</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Computer-assisted analysis of striated toolmarks and impressions</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2000</style></year></dates><secondary-title><style face="normal" font="default" size="100%">Second European Academy of Forensic Science Meeting</style></secondary-title><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>47</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Przemysław Kowalski</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Aleksandra Gruca</style></author><author><style face="normal" font="default" size="100%">Tadeusz Czachórski</style></author><author><style face="normal" font="default" size="100%">Stanisław Kozielski</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Visualization of heterogenic images of 3D scene</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2014</style></year></dates><secondary-title><style face="normal" font="default" size="100%">Man-Machine Interacions 3</style></secondary-title><electronic-resource-num><style face="normal" font="default" size="100%">10.1007/978-3-319-02309-0_31</style></electronic-resource-num><pages><style face="normal" font="default" size="100%">291–297</style></pages><abstract><style face="normal" font="default" size="100%">&lt;p&gt;The article presents a problem of 3D and 2D heterogenic data visualization. The data come from different devices installed on the robot platform. The data include 3D point cloud, 2D images, 3D and 2D occupancy grids, obtained from laser scanning device, stereocameras and calculated using data from laser 3D scanner.&lt;/p&gt;&#13;
</style></abstract><publisher><style face="normal" font="default" size="100%">Silesian University of Technology, Gliwice, Institute of Theoretical and Applied Informatics, Polish Academy of Science, Gliwice</style></publisher><language><style face="normal" font="default" size="100%">eng</style></language><notes><style face="normal" font="default" size="100%">ICMMI 2013 International Conference on Man-Machine Interactions Brenna, October 22-25, 2013</style></notes></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>47</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Leszek Luchowski</style></author><author><style face="normal" font="default" size="100%">Przemysław Kowalski</style></author><author><style face="normal" font="default" size="100%">Agnieszka Anna Tomaka</style></author><author><style face="normal" font="default" size="100%">Maciej Philipp</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Krzysztof Skabek</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Mobile Stereovision Strategies</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">1999</style></year><pub-dates><date><style face="normal" font="default" size="100%">X</style></date></pub-dates></dates><secondary-title><style face="normal" font="default" size="100%">II Krajowa Konferencja ,,Metody i systemy komputerowe w badaniach naukowych i projektowaniu inżynierskim”</style></secondary-title><pages><style face="normal" font="default" size="100%">531–536</style></pages><pub-location><style face="normal" font="default" size="100%">Kraków</style></pub-location><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Calculating the position of the observer in 3D using 2D images for the interactive presentation of virtual objects</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2010</style></year></dates><secondary-title><style face="normal" font="default" size="100%">Theoretical and Applied Informatics</style></secondary-title><pages><style face="normal" font="default" size="100%">177–186</style></pages><volume><style face="normal" font="default" size="100%">22</style></volume><number><style face="normal" font="default" size="100%">3</style></number><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">System of computer aiding diagnostic of Squint with applying analysis of the signal of the move of the eye</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2008</style></year></dates><secondary-title><style face="normal" font="default" size="100%">Theoretical and Applied Informatics</style></secondary-title><pages><style face="normal" font="default" size="100%">3–14</style></pages><volume><style face="normal" font="default" size="100%">20</style></volume><number><style face="normal" font="default" size="100%">1</style></number><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>47</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Zastosowanie systemu OBER2 w diagnostyce zeza</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2000</style></year></dates><secondary-title><style face="normal" font="default" size="100%">Journal of Medical Informatics and Technologies vol 5</style></secondary-title><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>47</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Segmentacja i pasowanie obrazów 2D dla potrzeb aktywnego stereowidzenia</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">1999</style></year></dates><pages><style face="normal" font="default" size="100%">81–84</style></pages><abstract><style face="normal" font="default" size="100%">W referacie przedstawiono metodę segmentacji i pasowania par obrazów stereo. Metoda ta została opracowana w wyniku prac prowadzonych w ramach projektu badawczego dotyczącego automatycznego rozpoznawania struktury trójwymiarowej sceny. Scena zbudowana jest z brył wielościennych i obserwowznz za pomocą ruchomej głowicy stereowizyjnej. Głównym celem projektu było rozpoznawanie obserwowanych brył geometrycznych oraz określanie ich wzajemnego położenia na scenie.</style></abstract><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>47</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Przemysław Kowalski</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Assumptions for a software tool to support the diagnosis of the stomatognathic system: data gathering, visualizing compund models and their motion</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2014</style></year><pub-dates><date><style face="normal" font="default" size="100%">3</style></date></pub-dates></dates><secondary-title><style face="normal" font="default" size="100%">Novel Methodology of Both diagnosis and Therapy of Bruxism</style></secondary-title><pages><style face="normal" font="default" size="100%">51–56</style></pages><abstract><style face="normal" font="default" size="100%">&lt;p&gt;The amount of measurement data collected in medical diagnostics makes their storage and handling an important issue. Also, the requirements for the visualization of such data, and for merging information from different sources of measurement, are growing. In the case of diagnosis of stomatognathic system we have to deal with various methods of medical imaging, such as CT, 3D scans, impressions of teeth, facial scans, and various types of reconstructions resulting from processing of measurement data. In the research project dedicated to the diagnosis of bruxism, we encounter records of measurements of Holter monitoring. We present a web application designed to collect the measurement data acquired in the project. In the first version, this tool has been prepared to store EKG files. We are planning further extension of the capabilities of the database to collect 3D scans, volumetric data and surfaces which are reconstructed from computed tomography. We also present assumptions for the user interface to the desktop application to assist the diagnosis. The application will allow to carry out morphometric measurements, the integration of multimodal imaging data, visualization of mandible movement in TMJ, occlusion detection and motion simulation of the mandible, and also the design of dental guard.&lt;/p&gt;&#13;
</style></abstract><publisher><style face="normal" font="default" size="100%">International Centre of Biocybernetics Polish Academy of Sciences</style></publisher><language><style face="normal" font="default" size="100%">eng</style></language><notes><style face="normal" font="default" size="100%">The 137th Seminar of the International Centre of biocybernetics</style></notes></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Przemysław Kowalski</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Programowe platformy dla zagadnień wizji komputerowej</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">1999</style></year></dates><secondary-title><style face="normal" font="default" size="100%">Zeszyty Naukowe Politechniki Śląskiej, Seria: Informatyka</style></secondary-title><pages><style face="normal" font="default" size="100%">57–81</style></pages><volume><style face="normal" font="default" size="100%">37</style></volume><number><style face="normal" font="default" size="100%">1421</style></number><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Przemysław Kowalski</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Kryteria pasowania punktów charaktery-stycznych w stereowizji</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">1998</style></year></dates><secondary-title><style face="normal" font="default" size="100%">Zeszyty Naukowe Politechniki Śląskiej, Seria: Informatyka</style></secondary-title><pages><style face="normal" font="default" size="100%">209–223</style></pages><volume><style face="normal" font="default" size="100%">35</style></volume><number><style face="normal" font="default" size="100%">1402</style></number><abstract><style face="normal" font="default" size="100%">Istotnym problemem, występującym w zagadnieniu stereowidzenia, z wykorzystaniem obrazu z dwu kamer, jest pasowanie punktów charakterystycznych. W artykule przedstawiamy zestaw pięciu testów, służących do pasowania punktów. Jest to test jasnościowy, dokonujący właściwego pasowania, oraz cztery testy geometryczne, dokonujące weryfikacji poprawności spasowania par punktów.</style></abstract><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>47</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Józef Ober</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Model of the oculomotoric system for diagnosis of Squint</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2006</style></year><pub-dates><date><style face="normal" font="default" size="100%">9</style></date></pub-dates></dates><secondary-title><style face="normal" font="default" size="100%"/></secondary-title><pages><style face="normal" font="default" size="100%">193–198</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><notes><style face="normal" font="default" size="100%">MIT 2006 Wisła-Malinka, September 25-27</style></notes></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>47</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Józef Ober</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Model of the oculomotoric system for diagnosis of Squint</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2004</style></year></dates><secondary-title><style face="normal" font="default" size="100%">International Workshop on Biometric Technologies: Special Forum on Modeling and Simulation</style></secondary-title><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>47</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Józef Ober</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Multilayer model of the oculomothoric system for computer based diagnosis of squint</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2003</style></year></dates><secondary-title><style face="normal" font="default" size="100%"/></secondary-title><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Krzysztof Skabek</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Optimization of Mesh Representation for Progressive Transmission</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2011</style></year></dates><secondary-title><style face="normal" font="default" size="100%">Theoretical and Applied Informatics</style></secondary-title><pages><style face="normal" font="default" size="100%">263–275</style></pages><volume><style face="normal" font="default" size="100%">23</style></volume><number><style face="normal" font="default" size="100%">3-4</style></number><abstract><style face="normal" font="default" size="100%">Abstract: The paper presents the implementation of methods for progressive mesh encoding. The described implementation is a modification of the software published in 2008 by Zhao He, which is based on studies by Michael Garland and Hugues Hoppe. We focused on improving the performance of the software. In particular we modified the data structures to ensure their better indexing, which significantly improved the computational complexity of the algorithm. We also implemented the support for simplified meshes with textures. The authors present the comparison of the performance of these methods in relation to the original He Zhao’s algorithm. The performance of progressive mesh encoding in our implementation was significantly improved.</style></abstract><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>47</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Krzysztof Skabek</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Ryszard Winiarczyk</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Progressive reduction of meshes with arbitrary selected points</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2016</style></year></dates><secondary-title><style face="normal" font="default" size="100%">Man-Machine Interactions 4</style></secondary-title><pages><style face="normal" font="default" size="100%">525–533</style></pages><abstract><style face="normal" font="default" size="100%">&lt;p&gt;The usage of progressive meshes for representation and transmission of triangular meshes of faces at certain level of details was described in the paper. We focused on progressive representation based on Garland and Hoppe approach. The comparison of simple methods using quadric mesh simplification to the view-dependent implementation of progressive methods was performed. The mesh simplification is further improved by introducing the characteristic points fixing the distinguishable points on human face. The test and discussion of the implemented method were given using face scans from 3dMD face scanner.&lt;/p&gt;&#13;
</style></abstract><publisher><style face="normal" font="default" size="100%">Springer International Publishing Switzerland</style></publisher><language><style face="normal" font="default" size="100%">eng</style></language><notes><style face="normal" font="default" size="100%">4th International Conference on Man-Machine interactions, ICMMI 2015 Kocierz Pass, Poland, October 6-9, 2015</style></notes></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>5</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Agnieszka Anna Tomaka</style></author><author><style face="normal" font="default" size="100%">Michał Tarnawski</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Ewa Piętka</style></author><author><style face="normal" font="default" size="100%">Pawel Badura</style></author><author><style face="normal" font="default" size="100%">Jacek Kawa</style></author><author><style face="normal" font="default" size="100%">Wojciech Wieclawek</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Multimodal Image Registration for Mandible Motion Tracking</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2016</style></year></dates><secondary-title><style face="normal" font="default" size="100%">Information Technologies in Medicine: 5th International Conference, ITIB 2016 Kamień Śląski, Poland, June 20 - 22, 2016 Proceedings, Volume 1</style></secondary-title><urls><style face="normal" font="default" size="100%">http://dx.doi.org/10.1007/978-3-319-39796-2_15</style></urls><electronic-resource-num><style face="normal" font="default" size="100%">10.1007/978-3-319-39796-2_15</style></electronic-resource-num><pages><style face="normal" font="default" size="100%">179–191</style></pages><isbn><style face="normal" font="default" size="100%">978-3-319-39796-2</style></isbn><publisher><style face="normal" font="default" size="100%">Springer International Publishing</style></publisher><pub-location><style face="normal" font="default" size="100%">Cham</style></pub-location><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>5</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Agnieszka Anna Tomaka</style></author><author><style face="normal" font="default" size="100%">Leszek Luchowski</style></author><author><style face="normal" font="default" size="100%">Krzysztof Skabek</style></author><author><style face="normal" font="default" size="100%">Michał Tarnawski</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Applying computational geometry to designing an occlusal splint</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2019</style></year><pub-dates><date><style face="normal" font="default" size="100%">05/2019</style></date></pub-dates></dates><secondary-title><style face="normal" font="default" size="100%">Computational Modeling of Objects Presented in Images. Fundamentals, Methods, and Applications. CompIMAGE 2018. Lecture Notes in Computer Science</style></secondary-title><electronic-resource-num><style face="normal" font="default" size="100%">10.1007/978-3-030-20805-9_16</style></electronic-resource-num><volume><style face="normal" font="default" size="100%">vol 10986</style></volume><publisher><style face="normal" font="default" size="100%">Springer International Publishing</style></publisher><pub-location><style face="normal" font="default" size="100%">Cham</style></pub-location><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>47</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Agnieszka Anna Tomaka</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Leszek Luchowski</style></author><author><style face="normal" font="default" size="100%">Michał Tarnawski</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Methods of Tooth Equator Estimation</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2018</style></year></dates><secondary-title><style face="normal" font="default" size="100%">Computer and Information Sciences</style></secondary-title><abstract><style face="normal" font="default" size="100%">&lt;p&gt;Full automation of the designing process of an occlusal splint requires an algorithm to determine the boundary of the splint. For this purpose, the idea of tooth equator is frequently used. The task is to find the approximate level where the teeth are widest, and then cut off the shape of the splint there. The article presents methods for automatic estimation of the tooth equator, used to determine the splint boundary.&lt;/p&gt;&#13;
</style></abstract><isbn><style face="normal" font="default" size="100%">978-3-030-00840-6</style></isbn><publisher><style face="normal" font="default" size="100%">Springer International Publishing</style></publisher><pub-location><style face="normal" font="default" size="100%">Cham</style></pub-location><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>5</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Agnieszka Anna Tomaka</style></author><author><style face="normal" font="default" size="100%">Leszek Luchowski</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Michał Tarnawski</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Dynamic Occlusion Surface Estimation from 4D Multimodal Data</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2019</style></year></dates><secondary-title><style face="normal" font="default" size="100%"> Information Technology in Biomedicine. ITIB 2019. Advances in Intelligent Systems and Computing</style></secondary-title><tertiary-title><style face="normal" font="default" size="100%">Advances in Intelligent Systems and Computing</style></tertiary-title><electronic-resource-num><style face="normal" font="default" size="100%">10.1007/978-3-030-23762-2_26</style></electronic-resource-num><volume><style face="normal" font="default" size="100%">vol 1011</style></volume><abstract><style face="normal" font="default" size="100%">&lt;p&gt;Methods are described of determining the dynamic occlusion surface based on dynamic sequences of mandibular motion, acquired with a dynamic scanner, and measurements acquired with the Zebris axiograph. The Zebris data is brought into register with multimodal imagery, using three corresponding transformations. This registration allows dense motion sequences to be simulated, which in turn allows occlusal conditions to be known at various stages of movement and the dynamic occlusal surface to be identified for the purposes of occlusal splint design.&lt;/p&gt;&#13;
</style></abstract><isbn><style face="normal" font="default" size="100%">978-3-030-23761-5</style></isbn><publisher><style face="normal" font="default" size="100%">Springer International Publishing</style></publisher><pub-location><style face="normal" font="default" size="100%">Cham</style></pub-location><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Agnieszka Anna Tomaka</style></author><author><style face="normal" font="default" size="100%">Leszek Luchowski</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Krzysztof Skabek</style></author><author><style face="normal" font="default" size="100%">Michał Tarnawski</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Applying computational geometry to designing an occlusal splint</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2019</style></year><pub-dates><date><style face="normal" font="default" size="100%">10/2019</style></date></pub-dates></dates><secondary-title><style face="normal" font="default" size="100%"/></secondary-title><urls><style face="normal" font="default" size="100%">https://www.tandfonline.com/doi/abs/10.1080/21681163.2019.1670096</style></urls><electronic-resource-num><style face="normal" font="default" size="100%">10.1080/21681163.2019.1670096</style></electronic-resource-num><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>5</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Agnieszka Anna Tomaka</style></author><author><style face="normal" font="default" size="100%">Leszek Luchowski</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Michał Tarnawski</style></author><author><style face="normal" font="default" size="100%">Krzysztof Domino</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">The dynamics of the stomatognathic system from 4D multimodal data</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2019</style></year></dates><secondary-title><style face="normal" font="default" size="100%">In A.Gadomski (ed.): Multiscale Locomotion: Its Active-Matter Addressing Physical Principles</style></secondary-title><urls><style face="normal" font="default" size="100%">http://arxiv.org/abs/1911.08854</style></urls><section><style face="normal" font="default" size="100%">3</style></section><abstract><style face="normal" font="default" size="100%">&lt;pre&gt;&#13;
  The purpose of this chapter is to discuss methods of acquisition,&#13;
visualization and analysis of the dynamics of a complex biomedical system,&#13;
illustrated by the human stomatognathic system. The stomatognathic system&#13;
consists of the teeth and the skull bones with the maxilla and the mandible.&#13;
Its dynamics can be described by the change of mutual position of the&#13;
lower/mandibular part versus the upper/maxillary one due to the physiological&#13;
motion of opening, chewing and swallowing. In order to analyse the dynamics of&#13;
the stomatognathic system its morphology and motion has to be digitized, which&#13;
is done using static and dynamic multimodal imagery like CBCT and 3D scans data&#13;
and temporal measurements of motion. The integration of multimodal data&#13;
incorporates different direct and indirect methods of registration - aligning&#13;
of all the data in the same coordinate system. The integrated sets of data form&#13;
4D multimodal data which can be further visualized, modeled, and subjected to&#13;
multivariate time series analysis. Example results are shown. Although there is&#13;
no direct method of imaging the TMJ motion, the integration of multimodal data&#13;
forms an adequate tool. As medical imaging becomes ever more diverse and ever&#13;
more accessible, organizing the imagery and measurements into unified,&#13;
comprehensive records can deliver to the doctor the most information in the&#13;
most accessible form, creating a new quality in data simulation, analysis and&#13;
interpretation.&lt;/pre&gt;&#13;
</style></abstract><publisher><style face="normal" font="default" size="100%"/></publisher><pub-location><style face="normal" font="default" size="100%">Bydgoszcz</style></pub-location><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>5</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Leszek Luchowski</style></author><author><style face="normal" font="default" size="100%">Agnieszka Anna Tomaka</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Michał Tarnawski</style></author><author><style face="normal" font="default" size="100%">Krzysztof Skabek</style></author><author><style face="normal" font="default" size="100%">Przemysław Kowalski</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Skanery3D - trójwymiarowe obrazowanie powierzchni</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2020</style></year></dates><secondary-title><style face="normal" font="default" size="100%">Inżynieria Biomedyczna - podstawy i zastosowania; Tom 8 - Obrazowanie Biomedyczne</style></secondary-title><section><style face="normal" font="default" size="100%">2.6</style></section><publisher><style face="normal" font="default" size="100%">AOW EXIT</style></publisher><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>5</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Agnieszka Anna Tomaka</style></author><author><style face="normal" font="default" size="100%">Michał Tarnawski</style></author><author><style face="normal" font="default" size="100%">Leszek Luchowski</style></author><author><style face="normal" font="default" size="100%">Bartosz Cerkaski</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Integracja obrazowania wielomodalnego w zastosowaniu do wspomagania diagnostyki stomatologicznej, planowania i oceny wyników leczenia</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2020</style></year></dates><secondary-title><style face="normal" font="default" size="100%">Inżynieria Biomedyczna - podstawy i zastosowania; Tom 8 - Obrazowanie Biomedyczne</style></secondary-title><section><style face="normal" font="default" size="100%">2.7</style></section><publisher><style face="normal" font="default" size="100%">AOW EXIT</style></publisher><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Leszek Luchowski</style></author><author><style face="normal" font="default" size="100%">Agnieszka Anna Tomaka</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Krzysztof Skabek</style></author><author><style face="normal" font="default" size="100%">Przemysław Kowalski</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Multimodal imagery in forensic incident scene documentation</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2021</style></year><pub-dates><date><style face="normal" font="default" size="100%">02/2021</style></date></pub-dates></dates><secondary-title><style face="normal" font="default" size="100%">Sensors</style></secondary-title><urls><style face="normal" font="default" size="100%">https://www.mdpi.com/1424-8220/21/4/1407</style></urls><electronic-resource-num><style face="normal" font="default" size="100%">10.3390/s21041407</style></electronic-resource-num><volume><style face="normal" font="default" size="100%">21</style></volume><issue><style face="normal" font="default" size="100%">4</style></issue><section><style face="normal" font="default" size="100%">1407</style></section><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Agnieszka Anna Tomaka</style></author><author><style face="normal" font="default" size="100%">Leszek Luchowski</style></author><author><style face="normal" font="default" size="100%">Michał Tarnawski</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Integration and application of multimodal measurement techniques: relevance of photogrammetry to orthodontics</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2021</style></year><pub-dates><date><style face="normal" font="default" size="100%">12/2021</style></date></pub-dates></dates><secondary-title><style face="normal" font="default" size="100%">Sensors</style></secondary-title><urls><style face="normal" font="default" size="100%">https://www.mdpi.com/1424-8220/21/23/8026</style></urls><electronic-resource-num><style face="normal" font="default" size="100%">10.3390/s21238026</style></electronic-resource-num><volume><style face="normal" font="default" size="100%">21</style></volume><issue><style face="normal" font="default" size="100%">23</style></issue><section><style face="normal" font="default" size="100%">8026</style></section><abstract><style face="normal" font="default" size="100%">&lt;p&gt;Multimodal imaging, including 3D modalities, is increasingly being applied in orthodontics, both as a diagnostic tool and especially for the design of intraoral appliances, where geometric accuracy is very important. Laser scanners and other precision 3D imaging devices are expensive and cumbersome, which limits their use in medical practice. Photogrammetry, using ordinary 2D photographs or video recordings to create 3D imagery, offers a cheaper and more convenient alternative, replacing&#160; the specialised equipment with handy consumer cameras. The present paper addresses the question to what extent, and under what conditions, this technique can be an adequate replacement for the 3D scanner. The accuracy of simple surface reconstruction and of model embedding achieved with photogrammetry was verified against that obtained with a triangulating laser scanner.&lt;/p&gt;&#13;
&#13;
&lt;p&gt;To roughly evaluate the impact of image imperfections on photogrammetric reconstruction, the photographs for photogrammetry were taken under various lighting conditions and used either raw or with a blur simulating defocus. Video footage was also tested as another 2D imaging modality feeding data into photogrammetry. Results show significant potential of photogrammetric techniques.&lt;/p&gt;&#13;
</style></abstract><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Mateusz Żarski</style></author><author><style face="normal" font="default" size="100%">Agnieszka Anna Tomaka</style></author><author><style face="normal" font="default" size="100%">Leszek Luchowski</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">dpVision: environment for multimodal images</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2025</style></year><pub-dates><date><style face="normal" font="default" size="100%">02/2025</style></date></pub-dates></dates><secondary-title><style face="normal" font="default" size="100%">SoftwareX</style></secondary-title><urls><style face="normal" font="default" size="100%">http://dx.doi.org/10.1016/j.softx.2025.102093</style></urls><electronic-resource-num><style face="normal" font="default" size="100%">10.1016/j.softx.2025.102093</style></electronic-resource-num><volume><style face="normal" font="default" size="100%">30</style></volume><issue><style face="normal" font="default" size="100%">102093</style></issue><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Agnieszka Anna Tomaka</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Michał Tarnawski</style></author><author><style face="normal" font="default" size="100%">Leszek Luchowski</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Transformation trees – documentation of multimodal image registration</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2025</style></year><pub-dates><date><style face="normal" font="default" size="100%">05/2025</style></date></pub-dates></dates><secondary-title><style face="normal" font="default" size="100%">Computers in Biology and Medicine</style></secondary-title><urls><style face="normal" font="default" size="100%">https://doi.org/10.1016/j.compbiomed.2025.110311</style></urls><electronic-resource-num><style face="normal" font="default" size="100%">10.1016/j.compbiomed.2025.110311</style></electronic-resource-num><volume><style face="normal" font="default" size="100%">193</style></volume><issue><style face="normal" font="default" size="100%">110311</style></issue><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Leszek Luchowski</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Visualization of a multidimensional point cloud as a 3D swarm of avatars</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2025</style></year><pub-dates><date><style face="normal" font="default" size="100%">06/2025</style></date></pub-dates></dates><secondary-title><style face="normal" font="default" size="100%">Applied Sciences</style></secondary-title><urls><style face="normal" font="default" size="100%">https://www.mdpi.com/2076-3417/15/13/7209</style></urls><electronic-resource-num><style face="normal" font="default" size="100%">10.3390/app15137209</style></electronic-resource-num><volume><style face="normal" font="default" size="100%">15</style></volume><issue><style face="normal" font="default" size="100%">7209</style></issue><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Agnieszka Anna Tomaka</style></author><author><style face="normal" font="default" size="100%">Leszek Luchowski</style></author><author><style face="normal" font="default" size="100%">Michał Tarnawski</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Computer-Aided Design of Personalized Occlusal Positioning Splints Using Multimodal 3D Data</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2025</style></year><pub-dates><date><style face="normal" font="default" size="100%">10/2025</style></date></pub-dates></dates><secondary-title><style face="normal" font="default" size="100%">Computer Vision and Image Understanding</style></secondary-title><urls><style face="normal" font="default" size="100%">https://doi.org/10.1016/j.cviu.2025.104527</style></urls><electronic-resource-num><style face="normal" font="default" size="100%">10.1016/j.cviu.2025.104527</style></electronic-resource-num><volume><style face="normal" font="default" size="100%">262C</style></volume><issue><style face="normal" font="default" size="100%">104527</style></issue><abstract><style face="normal" font="default" size="100%">&lt;p&gt;Digital technology plays a crucial role in designing customized medical devices, such as occlusal splints, commonly used in the management of disorders of the stomatognathic system. This methodological proof-of-concept study presents a computer-aided approach for designing and evaluating occlusal positioning splints. The primary aim is to demonstrate the feasibility and geometric accuracy of the proposed method at the preclinical stage. In this approach, a three-dimensional splint is generated using a transformation matrix to represent the therapeutic mandibular position. An experienced operator defines this position using a virtual patient model reconstructed from intraoral scans, CBCT, 3D facial scans, and a digitized plaster model. We introduce a novel method for generating splints that reproduces occlusal conditions in the therapeutic position and resolves surface conflicts through virtual embossing. The process for obtaining transformation matrices using dental tools and intraoral devices commonly employed in dental and laboratory workflows is described, and the geometric accuracy of both designed and printed splints is evaluated using profile and surface deviation analysis. The method supports reproducible, patient-specific splint fabrication and provides a transparent foundation for future validation studies, supporting multimodal image registration and quantification of occlusal discrepancies in research settings.&lt;/p&gt;&#13;
</style></abstract><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>47</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Wojciech Macek</style></author><author><style face="normal" font="default" size="100%">Mariusz Deja</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Mateusz Korpyś</style></author><author><style face="normal" font="default" size="100%">Cho-Pei Jiang</style></author><author><style face="normal" font="default" size="100%">Grzegorz Lesiuk</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Quantitative Techniques for Assessing Fatigue Damage After Failure</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2025</style></year><pub-dates><date><style face="normal" font="default" size="100%">09.2025</style></date></pub-dates></dates><secondary-title><style face="normal" font="default" size="100%">Book of Abstracts of the 3rd International Symposium on Risk Analysis and Safety of Complex Structures (September 11–12, 2025 in Wrocław, Poland)</style></secondary-title><urls><style face="normal" font="default" size="100%">https://iras2025.pwr.edu.pl/publication/macek-2025/</style></urls><abstract><style face="normal" font="default" size="100%">&lt;p&gt;A significant quantity of the fatigue life studies and a considerable number of fracture investigations have been carried out to measure changes associated with the damage process. However, there are cur-rently no set rules for the fractographical assessment of fatigue damage, and efforts are being made to find suitable techniques or alter current ones. Consequently, this study looks at two efficient post-failure techniques for identifying and quantifying damage. Fracture surface topography analysis, or FRASTA, has been used to solve a variety of failure problems. This quantified fractographic approach was first used in the early 1980s and has since been improved upon in tandem with developments in computing and measurement methods. To understand the behavior of a material under stress, especially in fatigue scenarios, the second methodology is known as the "entire fracture surface method" in mate-rial science. This method involves analyzing the entire surface of a fracture, or the broken surface pa-rameters. This approach aids in forecasting fatigue life and comprehending fatigue phenomena.&lt;/p&gt;&#13;
</style></abstract><publisher><style face="normal" font="default" size="100%">Wrocław University of Science and Technology</style></publisher><pub-location><style face="normal" font="default" size="100%">Wrocław, Poland</style></pub-location><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Wojciech Macek</style></author><author><style face="normal" font="default" size="100%">Mateusz Korpyś</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">FRASTA-toolbox: An Open Source Tool for Fracture-surface Analysis</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2026</style></year></dates><secondary-title><style face="normal" font="default" size="100%">SoftwareX</style></secondary-title><urls><style face="normal" font="default" size="100%">https://doi.org/10.1016/j.softx.2026.102788</style></urls><electronic-resource-num><style face="normal" font="default" size="100%">10.1016/j.softx.2026.102788</style></electronic-resource-num><abstract><style face="normal" font="default" size="100%">&lt;p&gt;FRASTA-toolbox is an open-source application for importing, preprocessing, and analyzing three-dimensional fracture-surface scan data. It provides an implementation of the FRASTA workflow, including grid interpolation, masking, alignment, cross-sectional profile analysis, and interactive two- and three-dimensional visualization based on PyQt5 and pyqtgraph. The software supports reproducible fracture-surface analysis and is applicable to research workflows in materials science, tribology, biomedical engineering, and digital forensics.&lt;/p&gt;&#13;
</style></abstract><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Wojciech Macek</style></author><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Przemysław Podulka</style></author><author><style face="normal" font="default" size="100%">Antonio Mourao</style></author><author><style face="normal" font="default" size="100%">Jose Correia</style></author><author><style face="normal" font="default" size="100%">Shun-Peng Zhu</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Qualitative and quantitative fractography of structural steel S235</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2026</style></year></dates><secondary-title><style face="normal" font="default" size="100%"/></secondary-title><urls><style face="normal" font="default" size="100%">https://onlinelibrary.wiley.com/doi/10.1111/ffe.70488</style></urls><electronic-resource-num><style face="normal" font="default" size="100%">10.1111/ffe.70488</style></electronic-resource-num></record><record><source-app name="Bibcite" version="8.x">Drupal-Bibcite</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Dariusz Pojda</style></author><author><style face="normal" font="default" size="100%">Krzysztof Domino</style></author><author><style face="normal" font="default" size="100%">Michał Tarnawski</style></author><author><style face="normal" font="default" size="100%">Agnieszka Anna Tomaka</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Transformation-driven generation of comparable projection images from multimodal anatomical scenes</style></title></titles><keywords/><dates><year><style face="normal" font="default" size="100%">2026</style></year></dates><secondary-title><style face="normal" font="default" size="100%">Journal of Computational Science (preprint available on arXiv)</style></secondary-title><urls><style face="normal" font="default" size="100%">http://arxiv.org/abs/2606.16573</style></urls><electronic-resource-num><style face="normal" font="default" size="100%">10.48550/arXiv.2606.16573</style></electronic-resource-num><abstract><style face="normal" font="default" size="100%">This work addresses the computational problem of generating reproducible projection-space observations from heterogeneous anatomical scenes whose components may undergo independent spatial transformations. We propose a transformation-driven framework for synthetic projection imaging from multimodal anatomical data and demonstrate it on mandibular-motion scenarios.&#13;
In contrast to conventional Digitally Reconstructed Radiograph (DRR) approaches primarily designed for registration, projection realism, or rendering efficiency, the proposed formulation treats projection imaging as an observation process operating on an explicitly represented anatomical scene.&#13;
Independently transformable volumetric and surface-based anatomical objects are embedded within a shared scene representation and propagated directly into projection space through explicit transformations. Projection geometry, acquisition modelling, material interpretation, and image presentation remain explicitly separated, enabling controlled exploration of methodological assumptions while preserving reproducibility and direct comparability between generated projections.&#13;
Particular emphasis is placed on transformation-driven anatomical scenarios relevant to craniofacial analysis, including mandibular motion and therapeutic repositioning. Using a shared anatomical reference scene composed of CT/CBCT volumes, segmented structures, surface models, and auxiliary anatomical or therapeutic objects, the framework enables generation of directly comparable VirtualRTG projections from multiple anatomical configurations while preserving identical imaging assumptions.&#13;
Rather than aiming at fully physically faithful radiographic simulation, the proposed approach provides a controllable and reproducible methodological environment for studying anatomy--projection relationships, motion observability, and transformation-aware imaging workflows.&#13;
</style></abstract></record></records></xml>
